Common Seal Failures Encountered in Production and Corresponding Mitigation Strategies
Release time: 2024-12-13
Common Seal Failures Encountered in Production and Corresponding Mitigation Strategies
During the operation of the machine, a sudden leak occurred in the mechanical seal, which contained gasoline, and the temperature reached 200 degrees Celsius. Upon disassembling and inspecting the seal, it was observed that the seal face exhibited excessive wear, and it was determined to be a single-face bellows mechanical seal.
The following issues were identified:
1. The moving ring has separated from the moving ring seat, and the moving ring is fractured;
2. The seal is significantly worn in both dynamic and static conditions;
3. Distinct narrow wear marks are present on the end face of the fractured moving ring;
**Cause Analysis of Seal Failure:**
1. The interaction between the moving ring and the moving ring seat is crucial. Both components experience thermal loading, and the selected base material exhibits differing linear expansion coefficients. Under high-temperature conditions, this disparity may lead to an improper interference fit, potentially resulting in the separation of the moving ring from the seat.
2. Observations indicate significant wear on the end face of the moving ring, characterized by darker wear scars. This suggests excessive heat generation and dry friction at the sealing interface, which may contribute to thermal deformation. If the sealing compression is excessive, it can intensify wear on the sealing surface. Furthermore, the ingress of particulate matter may exacerbate the wear conditions.
3. The seals operate under challenging environments, where elevated thermal stress can induce radial thermal cracks on the end face of the moving ring. Additionally, during pump start-up and shutdown, variations in axial force and vibrations in the pump body can lead to complete failure of the moving ring.
**Actions to Take in Case of Failure:**
1. Introduce sealed demineralized water to enhance the sealed operating environment.
2. Adjust the seal compression carefully to ensure it is not overly tight.
3. Prior to seal replacement, inspect the sealing components to verify their quality and condition.
During inspections of the reforming device, it is common to observe wear on the seal end face, signs of cavitation, blockages at the cooling inlet and outlet of the cooling chamber, and obstructions in the seal flushing liquid cooler.
**Root Cause Analysis:**
The pump operates with hot water exceeding 100 degrees Celsius, while the cooling medium for the seal flushing cooler is circulating water, which is prone to scaling. This scaling can obstruct the water chamber in the sealed cavity, leading to inadequate circulation in the self-flushing cooler. Consequently, the medium within the sealed cavity may vaporize, resulting in cavitation and dry wear on the seal end face, ultimately causing seal failure.
**Recommended Measures:**
1. Replace the heat exchanger with a unit that has a larger heat exchange area to prevent seal leakage caused by insufficient heat transfer.
2. Consider using softened water for cooling instead of circulating water to mitigate seal leakage issues resulting from cooling system blockages.