Three scenarios of water infiltration involving rubber sealing rings

Release time: 2024-10-25


Three scenarios of water infiltration involving rubber sealing rings.

During pressure testing or water flow operations, instances of water leakage at the rubber ring interface may occur intermittently.

The following factors are identified as potential causes:

1. Inversion of the Rubber Ring: This is the most frequently encountered issue. During the installation of the pipe, factors such as an uneven groove base, misalignment of the pipe insertion angle, inappropriate chamfering of the pipe groove, or improper placement of the rubber ring can lead to the ring being displaced forward. If the installation process does not include verification with a feeler gauge post-installation, the ring may be pushed out of the designated expansion groove.

2. Unsatisfactory Quality of the Rubber Gasket: The rubber gasket may possess defects such as pores, cracks, and seams. Additionally, the vulcanization process may be improperly timed, either excessively long or short, resulting in inadequate elasticity of the gasket.

3. Excessive Depth of the Expansion Groove: Equipment malfunctions occurring during the expansion process can result in the rubber ring being improperly seated. If the rubber ring does not extend beyond the groove surface but instead forms a concave shape within the groove, it will fail to achieve a proper seal.